TAF8 Human shRNA Lentiviral Particle (Locus ID 129685)

CAT#: TL301194V

TAF8 - Human shRNA lentiviral particles (4 unique 29mer target-specific shRNA, 1 scramble control), 0.5 ml each, >10^7 TU/ml.


Biosafety Sheet

USD 1,731.00

5 Weeks*

Size
    • 500 ul each

Product Images

Frequently bought together (2)
Control Lenti particles, Scrambled shRNA, Expressing GFP and Puro, >1x10^7 TU/ml, 0.5 ml
    • 1 x 10^7 TU/ml, 500 ul

USD 365.00


One-Wash Lentivirus Titer Kit, HIV-1 p24 ELISA
    • 96 reactions

USD 671.00

Other products for "TAF8"

Specifications

Product Data
Locus ID 129685
Synonyms II; TAF; TAF(II)43; TAFII-43; TAFII43; TBN
Vector pGFP-C-shLenti
Format Lentiviral particles
RefSeq BC033728, NM_138572, NM_138572.1, NM_138572.2, BC018796, BC119678, BC119679, NM_138572.3
UniProt ID Q7Z7C8
Summary This gene encodes one of several TATA-binding protein (TBP)-associated factors (TAFs), which are integral subunits of the general transcription factor complex TFIID. TFIID recognizes the core promoter of many genes and nucleates the assembly of a transcription preinitiation complex containing RNA polymerase II and other initiation factors. The protein encoded by this gene contains an H4-like histone fold domain, and interacts with several subunits of TFIID including TBP and the histone-fold protein TAF10. Alternatively spliced transcript variants have been described, but their biological validity has not been determined. [provided by RefSeq, Jul 2008]
shRNA Design These shRNA constructs were designed against multiple splice variants at this gene locus. To be certain that your variant of interest is targeted, please contact techsupport@origene.com. If you need a special design or shRNA sequence, please utilize our custom shRNA service.
Performance Guaranteed OriGene guarantees that the sequences in the shRNA expression cassettes are verified to correspond to the target gene with 100% identity. One of the four constructs at minimum are guaranteed to produce 70% or more gene expression knock-down provided a minimum transfection efficiency of 80% is achieved. Western Blot data is recommended over qPCR to evaluate the silencing effect of the shRNA constructs 72 hrs post transfection. To properly assess knockdown, the gene expression level from the included scramble control vector must be used in comparison with the target-specific shRNA transfected samples.

For non-conforming shRNA, requests for replacement product must be made within ninety (90) days from the date of delivery of the shRNA kit. To arrange for a free replacement with newly designed constructs, please contact Technical Services at techsupport@origene.com. Please provide your data indicating the transfection efficiency and measurement of gene expression knockdown compared to the scrambled shRNA control (Western Blot data preferred).

{0} Product Review(s)

0 Product Review(s) Submit review

Be the first one to submit a review

Product Citations

*Delivery time may vary from web posted schedule. Occasional delays may occur due to unforeseen complexities in the preparation of your product. International customers may expect an additional 1-2 weeks in shipping.